Termination Instructions: GORE® Ethernet Cables & TE Connectivity® CeeLok FAS-X® Connector System
Technical Information, 영어
W. L. Gore & Associates developed the following procedures based on our best practices for terminating our 4-pair Ethernet cables for Cat6A protocol with the TE Connectivity® CeeLok FAS-X® Connector System, pin and socket versions. By following these steps, you can maximize your assembly’s performance when connected to avionics and vectronics.
Please note: While these Termination Instructions offer a helpful guide, they should always be used alongside current connector system manufacturing instructions for best results.
About the Termination Instructions
These Termination Instructions are intended solely for terminating Gore’s 4-pair Cat6A Ethernet cables with the pin and socket versions of the TE Connectivity® CeeLok FAS-X® Connector System. They first detail the tools and materials you’ll need, which include:
- Needle nose pliers, scalpel, tweezer scissors, cutters or suitable equivalent tools
- Wire strippers (45-125)
- Polyimide tape (S-10518)
- Crimpers (M22520/2-01 / AFM8) and metal tweezer (M81969/8-01)
- Socket positioner M22520/2-07 (K40) and pin positioner M22520/2-09 (K42)
- Installation removal tool (M81969/14-01)
- Probe/pick
Preparing the cable and parts, terminating the pin connector (Termination A) and socket connector (Termination B), closing the connectors, and performing the required testing are all thoroughly covered with easy-to-follow, step-by-step instructions and photos to help you ensure proper termination.
Performing Required Testing
You should perform all required testing. Gore recommends the assembly should, at the minimum, be verified for proper wiring and continuity, and checked for shorts. You may be required to complete additional testing by local authorities and/or end-users. Gore recommends testing the final assembly using an advanced signal integrity tester such as the Fluke Networks® DSX-5000 or equivalent.
Contact a Gore Representative for More Information or Assistance
Terminating Gore’s wires and cables properly with connectors ensures high-speed data transmission with optimal signal integrity. These assembly termination instructions should only be used for the 4-pair design of GORE Ethernet Cables for Cat6A protocol with the pin and socket versions of the TE Connectivity® CeeLok FAS-X® Connector System.
Request a complimentary sample of our Ethernet cables for prototyping and evaluation in your application. If you’re ready to buy, contact a trusted distributor for in-stock availability.
If you need help with connector-cable compatibility and termination, contact a Gore representative for aerospace and defense today.
CeeLok FAS-X is a registered trademark of TE Connectivity.
Fluke Networks is a registered trademark of Fluke Corporation.
FOR INDUSTRIAL USE ONLY
Not for use in food, drug, cosmetic or medical device manufacturing, processing, or packaging operations.